CDC-50011: Combinational Logic Before Synchronizer Chain
Description
A CDC transfer has logic between its source and destination, and there is no handshake for the transfer. Without a handshake, the destination of the transfer behaves as the head of a synchronizer chain. However, a chain can only synchronize a signal that is the output of a register, not the output of combinational logic.
Recommendation
If you want to negotiate this transfer by a handshake, replace the existing CDC handshake circuit with the Bus Synchronizer Parameterizable Macro (ipm_cdc_bus_sync).
Refer to the documentation of Inserting HDL Code from a Provided Template in the Quartus Prime Pro Edition User Guide: Design Recommendations for instructions on adding (or instantiating) this macro.
To resolve the violation without replacing the circuit with the Bus Synchronizer Parameterizable Macro, attach it to a handshake. If the destination of the transfer is to act as a synchronizer chain, either remove the combinational logic on the transfer, or add a register after the combinational logic, with the register clocked by the source clock of the CDC transfer.
Severity
High
Tags
| Tag | Description |
|---|---|
| synchronizer | Design rule checks related to synchronizer chains. |
Device Family
- Cyclone® 10 GX
- Arria® 10
- Stratix® 10
- Agilex®
- Agilex®
- Agilex®
- Agilex®
- Agilex®