A clock signal source should drive only input clock ports of registers. Design Assistant Rule S104: Clock port and any other signal port of the same register should not be driven by the same source reports a violation only when your design contains clock signal sources that connect to ports other than the clock ports of the same register.
This rule is a sub-rule of Rule C104: Clock signal source should drive only input clock ports.